What is a certificate of occupancy?
It is the document the local building department issues to confirm that a building, or a space within it, complies with the codes and can be occupied for its intended use. It is usually needed after new construction, after a major renovation and whenever the use changes, for example when an office becomes a restaurant. Without it, a tenant may not be allowed to open.
What is a building permit, and does an interior project need one?
A building permit is permission from the local building department to carry out specific work, followed by inspections. Interior projects usually need one when they move or remove walls, alter the structure, change the layout of rooms or exits, or add or alter electrical, plumbing, gas or ventilation work. Painting, new flooring and like-for-like cabinet replacements often do not. The rules vary by place, so check with the local department before the design is fixed.
What does ADA compliant mean?
It means a space meets the 2010 ADA Standards for Accessible Design, the technical rules under the Americans with Disabilities Act. They apply to public accommodations, commercial facilities and state and local government buildings in the United States, including shops, restaurants, offices and hotels. Private homes are generally not covered, although state and local codes may add their own requirements.
What are the requirements for an ADA-compliant bathroom?
Under the 2010 ADA Standards, a single-user toilet room needs a 60 inch turning circle or a T-shaped turning space, a door with at least 32 inches of clear width, a toilet centred 16 to 18 inches from the side wall, grab bars on the side and rear walls mounted 33 to 36 inches above the floor, a sink no higher than 34 inches with knee space below, and a mirror whose reflecting surface starts no higher than 40 inches. Controls must work with one hand, without tight grasping or twisting.
What is the maximum slope of an ADA ramp?
The 2010 ADA Standards allow a running slope of no more than 1:12, which is one inch of rise for every 12 inches of run. Each run may rise at most 30 inches before a level landing, the cross slope may not exceed 1:48, and a ramp that rises more than 6 inches needs handrails on both sides. A gentler slope is easier for everyone.
What is the ADA counter height?
Sales and service counters need a section at least 36 inches long and no higher than 36 inches above the floor, so a wheelchair user can approach and be served. Work surfaces and dining surfaces for public use should be 28 to 34 inches high, with knee clearance below.
What is the minimum ADA door width?
A door must give at least 32 inches of clear width, measured with the door open at 90 degrees between the face of the door and the opposite stop. Thresholds may be no higher than half an inch, bevelled, and the door needs clear manoeuvring space on both sides and hardware that works without tight grasping.
What is an egress window?
An egress window is a window large enough for people to escape through and for firefighters to enter. In the United States, the International Residential Code requires one in every sleeping room and in habitable basements, with a net clear opening of at least 5.7 square feet, at least 24 inches high and 20 inches wide, and a sill no more than 44 inches above the floor. A basement bedroom without one cannot legally be called a bedroom.
What is the standard height of a handrail?
Both the International Residential Code and the International Building Code set stair handrails at 34 to 38 inches above the stair nosings. In England, Approved Document K sets 900 to 1000 mm. Handrails must be continuous and easy to grip, and accessible routes often need one on each side.
What is the building code for stairs?
Under the International Residential Code, a stair in a home may have risers of at most 7¾ inches and treads of at least 10 inches, with at least 6 feet 8 inches of headroom. The International Building Code is stricter for other buildings: risers of 4 to 7 inches and treads of at least 11 inches. Keep every riser and tread in a flight the same size: uneven steps cause falls.
What is a fire-rated door?
A fire-rated door is a complete door assembly, including the leaf, frame, hinges, closer, seals and any glazing, that has been tested to hold back fire for a set time, such as 20, 60 or 90 minutes. It carries a label, must close and latch on its own, and only performs as tested when installed as tested. Changing any part, from the hinges to a vision panel, can void the rating.